可程式化介電泳晶片設計:實現頻率與電壓可調控的細胞操控技術
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.catalog.0080 |
260413 | |
dc.catalog.00818 |
a | |
dc.catalog.00818 |
d | |
dc.catalog.00818 |
| | |
dc.catalog.00818 |
| | |
dc.catalog.0087 |
2025 | |
dc.catalog.020 |
平裝 | |
dc.catalog.041 |
chi | |
dc.catalog.041 |
eng | |
dc.catalog.300c |
30 | |
dc.contributor.advisor |
李鎮宜 | |
dc.contributor.advisor |
Lee, Chen-Yi | |
dc.contributor.author |
連紹華 | |
dc.contributor.author |
Lian, Shao-Hua | |
dc.contributor.campus |
光復 | |
dc.contributor.college |
電機學院 | |
dc.contributor.committee |
李鎮宜 | |
dc.contributor.committee |
張錫嘉 | |
dc.contributor.committee |
陳文亮 | |
dc.contributor.committee |
Lee, Chen-Yi | |
dc.contributor.committee |
Chang, Hsie-Chia | |
dc.contributor.committee |
Chen, Wen-Liang | |
dc.contributor.department |
電子研究所 | |
dc.contributor.idpcode |
3510 | |
dc.contributor.studentid |
312510137 | |
dc.date.NCLavailable |
2025/11/20 | |
dc.date.USTavailable |
2025/11/20 | |
dc.date.issued |
2025 | |
dc.date.issuedROC |
114 | |
dc.date.paperavailable |
立即公開 | |
dc.date.schoolyear |
114 | |
dc.description.abstract |
本論文提出了兩款具備可程式化設計的CMOS 介電泳(DEP) 陣列晶片,分別針對驅 動電壓和訊號頻率進行優化調控,核心目標為實現高效能的微小粒子與生物細胞操縱。 相較於前代晶片,這兩款設計不僅解決了易損壞的可靠性問題,更透過不同的架構改 良,顯著增加了可產生的DEP 作用力。這使得晶片的操作彈性大幅提升,能根據不同 的實驗目標,設定最適合的參數組合,從而達到更優異的操控效果。除此之外,透過 對客製化軟體介面(GUI)和控制程式的改良,系統賦予了使用者根據晶片運行即時狀 態靈活調整電極陣列控制圖形的能力,進一步提升了粒子與細胞操控的即時性和精確 性。這些技術上的突破和系統層面的改進,使得此CMOS 介電泳陣列晶片在細胞移動、 分離與純化等複雜操作上展現出更高的便利性、效率與可靠度,並具備應用於生物科 技與臨床醫學的巨大潛力。 | |
dc.description.abstract |
This research presents two programmable CMOS Dielectrophoresis (DEP) array chips, optimized for the regulation of driving voltage and signal frequency. The core goal is to realize high-performance manipulation of microparticles and biological cells. Compared to previous generation chips, these two designs not only resolved the issue of unreliability but also utilized distinct architectural improvements to significantly increase the achievable DEP force. This enhancement boosts the operational flexibility of the chip, enabling the setting of optimal parameter combinations suited to different experimental objectives, thus achieving superior manipulation efficacy. Furthermore, through the improvement of the customized GUI, the system empowers users to flexibly adjust the electrode array control patterns based on the real time status of the chip operation, which further elevates the immediacy and precision of particle and cell manipulation. In conclusion, these technological breakthroughs and system level enhancements render the CMOS DEP array chip with higher convenience, efficiency, and reliability for complex operations such as cell movement, separation, and purification, demonstrating immense potential for applications in biotechnology and clinical medicine. | |
dc.description.abstractopendate |
2025/11/20 | |
dc.description.degree |
碩士 | |
dc.description.tableofcontents |
Chinese Abstract ..................................................................................................................... i English Abstract...................................................................................................................... ii 1 Introduction....................................................................................................................... 1 1.1 Motivation ................................................................................................................ 2 1.2 Thesis Organization ................................................................................................. 4 2 Literature Review.............................................................................................................. 5 2.1 DEP Systems............................................................................................................ 5 2.1.1 CMOS-Based DEP Chips ............................................................................... 7 2.2 Waveform Effects on DEP Force ............................................................................. 8 2.3 Voltage and Frequency Dependence of DEP........................................................... 10 2.4 Cell Viability in DEP Manipulation......................................................................... 11 2.5 Demand in Biological Applications......................................................................... 12 2.6 Summary.................................................................................................................. 12 3 Design of Programmable DEP Array ............................................................................... 14 3.1 proDEP_HighV Chip............................................................................................... 14 3.1.1 Architecture..................................................................................................... 14 3.1.2 Pixel Circuit Design........................................................................................ 15 3.1.3 Pixel Function Simulation Results.................................................................. 17 3.1.4 Scan Chain Simulation Results....................................................................... 18 3.2 proDEP_Digital Chip............................................................................................... 18 3.2.1 Architecture..................................................................................................... 18 3.2.2 Pixel Circuit Design........................................................................................ 20 3.2.3 Pixel Function Simulation Results.................................................................. 22 3.2.4 On-Chip Signal Generation............................................................................. 23 3.2.5 Data Loading and Global Signal Distribution ................................................ 25 3.3 Scalability ................................................................................................................ 25 3.4 Electrode Design consideration ............................................................................... 26 3.5 Biocompatible Packaging ........................................................................................ 26 3.6 Summary and Comparison....................................................................................... 28 4 Experiment Results and Discussion.................................................................................. 31 4.1 Experimental Setup.................................................................................................. 31 4.1.1 Chip Operation System Architecture .............................................................. 31 4.1.2 Pattern Generation .......................................................................................... 33 4.1.3 Experimental Procedure.................................................................................. 34 4.2 Particle Experiment Results and Discussion............................................................ 36 4.2.1 Different Voltages Experiment........................................................................ 36 4.2.2 Different Waveforms Experiment ................................................................... 37 4.2.3 Different Frequencies Experiment.................................................................. 38 4.3 Cell Experiment Results .......................................................................................... 40 4.3.1 Different Voltages Experiment........................................................................ 40 4.3.2 Different Waveforms Experiment ................................................................... 41 4.3.3 Different Frequencies Experiment.................................................................. 42 4.4 Summary of Experiment.......................................................................................... 43 5 Conclusion and Future Work ............................................................................................ 45 5.1 Conclusion ............................................................................................................... 45 5.2 Future Work ............................................................................................................. 46 5.2.1 Chip Design Enhancement.............................................................................. 46 5.2.2 Chip Function Integration ............................................................................... 48 References............................................................................................................................... 49 | |
dc.format |
||
dc.identifier.citation |
[1] Y. Ma, Z. Liang, Y. Chen, and J. Wang, “Advances in precise cell manipulation,” Droplet, vol. 4, no. 1, p. 149, jan 2025. [Online]. Available: https://onlinelibrary.wiley.com/doi/10. 1002/dro2.149 [2] H. Guo and Z. Li, “Optical tweezers technique and its applications,” Science China Physics, Mechanics & Astronomy, vol. 56, no. 12, pp. 2351–2360, nov 2013. [Online]. Available: https://link.springer.com/article/10.1007/s11433-013-5355-3 [3] J. V. I. Timonen, C. Raimondo, D. Pilans, P. P. Pillai, and B. A. Grzybowski, “Trapping, manipulation, and crystallization of live cells using magnetofluidic tweezers,” Nanoscale Horizons, vol. 2, no. 1, pp. 50–54, 2017. [Online]. Available: https://pubs.rsc.org/en/content/articlelanding/2017/nh/c6nh00104a [4] H. A. Pohl, “The Motion and Precipitation of Suspensoids in Divergent Electric Fields,” Journal of Applied Physics, vol. 22, no. 7, pp. 869– 871, jul 1951. [Online]. Available: https://pubs.aip.org/jap/article/22/7/869/159853/ The-Motion-and-Precipitation-of-Suspensoids-in [5] W.-Y. Lin, L.-H. Lai, Y.-W. Lin, and C.-Y. Lee, “A Programmable CMOS Dielectrophoresis Array Chip with 128x128 Electrodes for Cell Manipulation,” in IEEE International Symposium on Circuits and Systems (ISCAS), 2024, pp. 1–5. [Online]. Available: https://ieeexplore.ieee.org/document/10558251 [6] N. P. Boldt, L. Weirauch, J. M. Späth, U. Kerst, M. Birkholz, M. Baune, and R. Thewes, “When to Use Rectangular Waveforms in Dielectrophoresis: Application to Increase Separation and Sorting Efficiency,” Electrophoresis, vol. 46, no. 1-2, pp. 104–111, jan 2025. [Online]. Available: https://analyticalsciencejournals.onlinelibrary.wiley.com/doi/ 10.1002/elps.202400164 [7] H. A. Pohl and I. Hawk, “Dielectrophoretic force: A Comparison of Theory and Experiment,” Journal of Biological Physics, vol. 6, no. 3, pp. 133–160, sep 1978. [Online]. Available: https://link.springer.com/article/10.1007/BF02328936 [8] R. Pethig, “Dielectrophoresis: Status of the Theory, Technology, and Applications,” Biomicrofluidics, vol. 4, no. 2, p. 022811, jun 2010. [Online]. Available: https: //doi.org/10.1063/1.3456626 [9] H. Matbaechi Ettehad, R. K. Yadav, S. Guha, and C. Wenger, “Towards CMOS Integrated Microfluidics Using Dielectrophoretic Immobilization,” Biosensors, vol. 9, no. 2, p. 77, jun 2019. [Online]. Available: https://doi.org/10.3390/bios9020077 [10] T. J. Kwak, I. Hossen, R. Bashir, W.-J. Chang, and C. H. Lee, “Localized Dielectric Loss Heating in Dielectrophoresis Devices,” Scientific Reports, vol. 9, p. 18977, dec 2019. [Online]. Available: https://doi.org/10.1038/s41598-019-55031-y [11] T. P. Hunt, D. Issadore, and R. M. Westervelt, “Integrated circuit/microfluidic chip to programmably trap and move cells and droplets with dielectrophoresis,” Lab on a Chip, vol. 8, no. 1, pp. 81–87, nov 2007. [Online]. Available: https://pubs.rsc.org/en/content/articlelanding/2008/lc/b710928h [12] D. Lee, D. Jung, F. Jiang, G. W. Junek, J. Park, H. Liu, Y. Kong, A. Wang, Y. Kim, K.-S. Choi, J.Wang, and H.Wang, “A Multi-Functional CMOS Biosensor Array With On-Chip DEP-Assisted Sensing for Rapid Low-Concentration Analyte Detection and Close-Loop Particle Manipulation With No External Electrodes,” IEEE Transactions on Biomedical Circuits and Systems, vol. 17, no. 6, pp. 1214–1226, feb 2023. [Online]. Available: https://ieeexplore.ieee.org/document/10360258 [13] G. Contreras-Dávila, J. I. Gomez-Quiñones, V. H. Pérez-González, and R. Martinez- Duarte, “Assessing the advantages of using square wave signals for particle trapping in carbon-electrode dielectrophoresis,” ECS Transactions, vol. 72, no. 1, pp. 105–114, 2016. [Online]. Available: https://doi.org/10.1149/07201.0105ecst [14] F. C. Jammes and S. J. Maerkl, “How single-cell immunology is benefiting from microfluidic technologies,” Microsystems & Nanoengineering, vol. 6, no. 1, p. 45, 2020. [Online]. Available: https://doi.org/10.1038/s41378-020-0140-8 [15] Y.-S. Chan, T.-T. Hsu, Y.-P. Chen, H.-M. Wu, Y.-M. Wang, and C.-Y. Lee, “A Traveling- Wave Dielectrophoresis Bio-Chip for Cell Manipulation in Standard Cmos Process,” IEEE Transactions on Circuits and Systems II: Express Briefs, vol. 69, no. 3, pp. 1582–1586, Mar. 2022. [Online]. Available: https://ieeexplore.ieee.org/document/9507525 | |
dc.identifier.uri |
https://hdl.handle.net/20.500.14371/87635 | |
dc.language.iso |
英文 | |
dc.relation.page |
51 | |
dc.subject.keyword |
介電泳 | |
dc.subject.keyword |
生物晶片 | |
dc.subject.keyword |
Dielectrophoresis | |
dc.subject.keyword |
CMOS biochip | |
dc.title |
可程式化介電泳晶片設計:實現頻率與電壓可調控的細胞操控技術 | zh-TW |
dc.title |
Programmable Dielectrophoresis Chips with Frequency and Voltage Scaling for Cell Manipulation | en |
dc.type |
Thesis | zh-TW |
檔案
- yOjuKMErh.pdf (14.9 MB, Adobe PDF)
所屬典藏: 電子研究所