單光子雪崩二極體之漸進保護環結構與光子統計測試
Gradient Guard Ring Structure and Photon Statistics Testing of Single-Photon Avalanche Diodes
摘要
本論文第一部分旨在解決單光子雪崩二極體在尺寸微縮時所面臨的性能瓶頸。光達與成像陣列對高密度像素的需求增加,也提高了對小尺寸元件的要求,但傳統結構在小尺寸下會產生邊界效應,導致崩潰電壓上升且光子偵測機率大幅下降。為此,本研究採用基於 TSMC 0.18 μm BCD 製程的「漸進式保護環」結構,利用熱退火形成的濃度梯度來修飾主動區邊緣的電場分佈。透過設計不同寬度的保護環進行量測,結果證實200 nm寬度的GGR設計能有效抑制邊界效應,元件效能的優化最為顯著。本論文第二部分則探討光子統計實驗的測試,延伸自1950年Hanbury-Brown與 Twiss用於量測恆星角直徑的強度干涉儀原理。本研究將此天文觀測概念應用於微觀的光子統計檢測,利用實驗室的SPAD晶片架設HBT干涉儀,針對不同波長的雷射光與類熱源光進行二次相關性函數量測。實驗結果顯示,系統能準確解析出同調光的帕松分佈特性;而在熱源光量測上,雖受限於探測器時間解析度與光源同調時間的差異,未能完全解析出完整的群聚峰值,但穩定脈衝光的量測驗證了本次光學架設及SPAD 進行光子統計實驗的可行性,並從實驗結果分析熱源光群聚觀測所需的改進方向。
The first part of this thesis aims to address the performance bottlenecks encountered in Single-Photon Avalanche Diodes (SPADs) during device miniaturization. The increasing demand for high-density pixels in LiDAR and imaging arrays has heightened the requirements for small-sized devices. However, traditional structures suffer from edge effects when scaled down, resulting in increased breakdown voltages and a significant reduction in Photon Detection Probability (PDP). To address this, this study adopts a "Gradient Guard Ring (GGR)" structure based on the TSMC 0.18 μm BCD process, utilizing concentration gradients formed by thermal annealing to modify the electric field distribution at the edge of the active region. Through the design and measurement of guard rings with varying widths, experimental results confirm that the 200 nm GGR design effectively suppresses edge effects, yielding the most significant optimization in device performance.The second part of this thesis investigates photon statistics testing, extending from the intensity interferometer principle developed by Hanbury-Brown and Twiss in the 1950s for measuring stellar angular diameters. This study applies this astronomical observation concept to microscopic photon statistical detection. An HBT interferometer was constructed using SPAD chips developed in our laboratory to measure the second-order correlation function of laser light and thermal-like light across different wavelengths. Experimental results demonstrate that the system can accurately resolve the Poissonian distribution characteristics of coherent light. Regarding thermal light measurements, although the complete bunching peak could not be fully resolved due to limitations in the detector's time resolution relative to the light source's coherence time, measurements of stable pulsed light verified the feasibility of the optical setup and the use of these SPADs for photon statistics experiments. Furthermore, necessary improvements for observing thermal light bunching were analyzed based on the experimental results.