一種可用於生物醫學的替代性液壓動力源

An alternative hydraulic power source for biomedical applications

檔案

日期

2026

類型

語言

英文

摘要

本研究旨在開發一種基於溫敏性聚合物與光熱奈米材料的微型複合水凝膠致動器,以解決傳統微型載具在複雜微血管環境中面臨的推力不足與生物安全性挑戰。研究選用 N-異丙基丙烯醯胺 (NIPAm) 作為溫敏骨架,並導入氧化銫鎢 (CsWO3) 奈米粒子作為高效光熱轉換劑。透過二步連續聚合法製備出不對稱雙層結構(PNIPAm / PNIPAm@CsWO3),有效克服了奈米粒子對聚合物鏈收縮的物理阻礙,使其兼具高效光熱吸收與大幅度體積變形能力。為了驗證致動器在真實生理環境下的運作效能,本研究利用 Arduino Uno 結合步進馬達建構了一套「模擬心臟搏動平台」,成功模擬出具備脈動特性的流場。實驗結果顯示,在濃度 20.5 mg/ml 的 CsWO3 摻雜與 300 mW (10 W/cm2) 的 980 nm 近紅外光照射下,系統熱平衡溫度有最高的溫度41.6°C,既能跨越下臨界溶解溫度 (LCST) 引發相變,也接近人體生理溫度。在流速 1.78 cm/s 的模擬脈動流場中,該致動器展現了抗沖刷能力,達成 207 μm 的淨位移。此外,動態流體產生的對流傳熱效應顯著提升了材料的冷卻效率,確保致動器具備優異的週期性熱穩定性。本研究證實了光熱驅動水凝膠致動器作為血管內主動式微創清理的潛力。
This study aims to develop a micro-composite hydrogel actuator based on thermo-responsive polymers and photothermal nanomaterials (NPs) to address the challenges of insufficient thrust and biosafety risks faced by conventional micro-vehicles in complex microvascular environments. N-isopropylacrylamide (NIPAm) was selected as the thermo-responsive backbone, and cesium tungsten oxide (CsWO3) NPs were incorporated as high-efficiency photothermal agents. An asymmetric bilayer structure (PNIPAm / PNIPAm@CsWO3) was fabricated via a two-step sequential polymerization method, effectively overcoming the physical hindrance of NPs to polymer chain contraction and achieving both high-efficiency photothermal absorption and substantial volumetric deformation. To validate the actuator's operational performance in a real physiological environment, this study constructed a "cardiac pulsation-mimicking platform" using an Arduino Uno integrated with a step motor, successfully simulating a flow field with pulsatile characteristics.
Experimental results showed that with a 20.5 mg/ml CsWO3 doping concentration and 300 mW (10 W/cm2) of 980 nm near-infrared (NIR) irradiation, the system achieved the highest thermal equilibrium temperature 41.6°C. This temperature not only crosses the lower critical solution temperature (LCST) to trigger the phase transition but also remains close to human physiological temperature. In a simulated pulsatile flow field at 1.78 cm/s, the actuator demonstrated washout resistance and achieved a net displacement of 207 μm. Furthermore, the convective heat transfer effect generated by the dynamic fluid significantly improved the cooling efficiency of the material, ensuring the actuator possesses excellent cyclic thermal stability. This study confirms the potential of photothermal-driven hydrogel actuators for active minimally invasive intravascular clearance.
顯示完整詮釋資料 統計資料

引用此條目

Chen, M.-Y. (2026). An alternative hydraulic power source for biomedical applications. https://thesis.lib.nycu.edu.tw/handle/20.500.14371/88973

BibTeX RIS

引用文字依 APA 第 7 版格式自動產生,使用前請再核對。

分享

永久網址:https://thesis.lib.nycu.edu.tw/handle/20.500.14371/88973