雙面透氣之氣體感測元件

Dual-Side Gas-Permeable Gas Sensor

檔案

日期

2026

類型

語言

中文

摘要

硫化氫(H2S)為人體口腔與腸胃道健康之重要生物標記,其濃度與口臭、牙周疾病及腸胃道菌相失衡密切相關,臨床判別濃度約落於 50–185 ppb;若能以可穿戴、非侵入之方式即時偵測數十至數百 ppb 之 H2S,將有助於相關疾病之早期篩檢與長期監測。然而,穿戴式感測元件須長時間貼附於人體,透氣性至關重要,元件須使空氣與皮膚水氣自由穿透,方能兼顧配戴舒適度,並使目標氣體更有效率地接觸感測層。有鑑於此,本研究開發一種可於室溫操作、可撓且上下雙面透氣之 MXene 導電紙/氧化銅(CuO)H2S 氣體感測元件。元件以對 H2S 具高選擇性之 p 型半導體 CuO 作為感測材料,搭配同時具備導電性與透氣性之 MXene 導電紙作為電極,並以鈦網(Ti mesh)支撐與保護;有別於以往以 ITO 玻璃為基板、氣體僅能單面進入之結構,本研究採鈦網/MXene 導電紙/CuO/MXene 導電紙/鈦網之上下對稱透氣結構,使氣體得以自上、下兩面同時穿透電極並進入感測層。
於室溫、操作電壓 5 V 之條件下,元件對 50–1000 ppb 之 H2S 產生濃度相依之電流響應,此範圍恰涵蓋前述人體相關之臨床濃度區間,且對 CO、NO、NO2、NH3 等氣體幾乎無響應,顯示對 H2S 之高選擇性。新結構最主要之改善為量測重複性:舊式單面透氣元件對 H2S 之響應不具重複性,僅首次量測能測得明顯響應,其後即無法再現相同響應;上下透氣新結構則可反覆重現相同濃度之響應,大幅提升元件之可重複使用性。
由於實驗條件之限制,本研究尚未直接以人體呼氣或口腔氣體進行驗證,遂改以鮭魚腐敗所釋放之氣體作為真實且動態之生物 H2S 來源進行驗證,其 H2S 濃度恰由數百 ppb 動態上升至數千 ppb,與前述臨床關注之濃度區間重疊。實驗中,所量測之 H2S 濃度於腐敗 6 小時內維持在約 400 ppb 以下,其後顯著上升,至 24 小時達約 4466 ppb;藉由感測響應與 H2S 濃度之檢量線,即可由元件訊號推估其釋放之氣體濃度,進而評估腐敗程度。此結果除證實本元件可應用於即時水產品新鮮度監測外,亦驗證其對生物來源微量 H2S 之即時定量能力,為其未來延伸至穿戴式人體健康監測提供依據。綜言之,此一可重複使用、室溫操作、可撓且雙面透氣之感測元件,於人體健康監測與食品安全評估上均具應用潛力。
Hydrogen sulfide (H2S) is an important biomarker of human oral and gastrointestinal health; its concentration is closely associated with halitosis, periodontal disease, and gut microbial imbalance, with a clinically relevant range of roughly 50–185 ppb. A wearable, non-invasive means of detecting tens to hundreds of ppb of H2S in real time would therefore aid the early screening and long-term monitoring of such conditions. However, because a wearable sensor must remain attached to the body for extended periods, gas permeability is essential: the device must allow air and skin moisture to pass through freely, both to ensure wearing comfort and to let the target gas reach the sensing layer more efficiently. To this end, this study develops a room-temperature, flexible, dual-side gas-permeable H2S gas sensor based on MXene conductive paper and copper oxide (CuO). The p-type semiconductor CuO, which is highly selective to H2S, is used as the sensing material, together with electrically conductive and gas-permeable MXene paper as the electrodes, supported and protected by titanium (Ti) mesh. In contrast to previous structures built on an ITO glass substrate, in which gas can enter from only one side, a vertically symmetric, dual-side-permeable structure (Ti mesh / MXene paper / CuO / MXene paper / Ti mesh) is adopted so that gas can penetrate the electrodes and enter the sensing layer from both the top and the bottom.
At room temperature and an operating voltage of 5 V, the device exhibits a concentration-dependent current response to H2S over 50–1000 ppb, a range that covers the clinically relevant concentrations noted above, while showing almost no response to CO, NO, NO2, and NH3, indicating high selectivity to H2S. The principal improvement of the new structure is measurement repeatability: the previous single-side device could measure H2S reliably only on the first attempt and could not reproduce the response afterwards, whereas the dual-side structure repeatedly reproduces the response at the same concentration, greatly enhancing the reusability of the device.
Owing to experimental constraints, human breath or oral gas was not tested directly; instead, the gas released during salmon spoilage was used as a real, dynamic biological source of H2S for validation, as its H2S concentration rises dynamically from hundreds to thousands of ppb, overlapping the clinically relevant range. In the experiment, the measured H2S concentration remained below about 400 ppb within the first 6 hours of spoilage and then rose markedly, reaching about 4466 ppb at 24 hours; using the calibration curve between the sensor response and the H2S concentration, the concentration of the released gas, and hence the degree of spoilage, can be estimated from the device signal. These results not only demonstrate the device's applicability to real-time seafood-freshness monitoring but also verify its ability to quantify biologically released trace H2S in real time, providing evidence for its future extension to wearable human health monitoring. Overall, this reusable, room-temperature, flexible, dual-side gas-permeable sensor shows promise for both human health monitoring and food-safety assessment.