應用多項生理訊號進行之失智篩檢系統之開發與驗證
Development and validation of a dementia screening system using multiple physiological signals
摘要
緒論:隨著人口高齡化,失智症相關照護需求持續增加。現行認知功能評估與神經影像雖具臨床價值但同時存在限制,較難直接應用於社區大規模篩檢。腦電圖 (Electroencephalogram, EEG) 具有非侵入性與高時間解析度等特性,過去研究指出失智症患者腦波呈現 EEG slowing 現象、神經網路活動改變及訊號複雜度下降等特徵。然而目前多數 EEG 研究仍以醫療院所或研究型設備為主。目標:本研究旨在開發一套可同步擷取多項生理訊號之穿戴式裝置,醫療器材法規及 EEG 分析應用之整合架構,建立兼具可負擔性 (Affordable)、可近性 (Accessible) 與準確性 (Accurate) 之社區認知障礙風險篩檢
輔助系統。資料與方法:本研究設計涵蓋儀器硬體架構與訊號擷取模組開發,以支援EEG、心電圖 (Electrocardiogram, ECG)、眼電圖 (Electroretinogram, EOG) 及三軸加速度訊號之同步量測與資料紀錄。依醫療器材要求完成產品定位、技術文件、品質管理及安全與性能檢驗資料。並於社區及失智照護據點進行收案,研究以 resting-state EEG 分別評估 Theta/Alpha Ratio 與既有非線性失智症篩檢模型所產生之 Huang Index 分類效能。研究結果:Theta/Alpha Ratio 結果顯示認知障礙組具有較高數值,與既有 EEG slowing 趨勢一致;Huang Index 分類結果顯示準確率為 0.84,曲線下面積(Area Under the Curve, AUC) 為 0.81,顯示具備認知障礙風險區辨之初步可行性。結論:本研究完成一套穿戴式多生理訊號裝置並於社區場域進行失智症篩檢輔助工具之初步驗證。未來在取得醫療器材認證預期可進一步導入臨床場域作為醫療研究與臨床健康監測之工具。
輔助系統。資料與方法:本研究設計涵蓋儀器硬體架構與訊號擷取模組開發,以支援EEG、心電圖 (Electrocardiogram, ECG)、眼電圖 (Electroretinogram, EOG) 及三軸加速度訊號之同步量測與資料紀錄。依醫療器材要求完成產品定位、技術文件、品質管理及安全與性能檢驗資料。並於社區及失智照護據點進行收案,研究以 resting-state EEG 分別評估 Theta/Alpha Ratio 與既有非線性失智症篩檢模型所產生之 Huang Index 分類效能。研究結果:Theta/Alpha Ratio 結果顯示認知障礙組具有較高數值,與既有 EEG slowing 趨勢一致;Huang Index 分類結果顯示準確率為 0.84,曲線下面積(Area Under the Curve, AUC) 為 0.81,顯示具備認知障礙風險區辨之初步可行性。結論:本研究完成一套穿戴式多生理訊號裝置並於社區場域進行失智症篩檢輔助工具之初步驗證。未來在取得醫療器材認證預期可進一步導入臨床場域作為醫療研究與臨床健康監測之工具。
Introduction: With the aging population, dementia-related care demands continue to increase. Electroencephalography (EEG) provides a non-invasive approach for dementia-related assessment; however, most studies rely on clinical or research-grade equipment, limiting commu
nity applications.Objective: This study aimed to develop a wearable multi-physiological signal device integrating medical device regulatory requirements and EEG analysis for community based cognitive impairment risk screening with improved affordability, accessibility, and accu
racy.Materials and Methods: A wearable device was developed to acquire EEG, electrocardiography (ECG), electrooculography (EOG), and three-axis acceleration signals. Participantswere recruited from community settings and dementia care sites, and resting-state EEG signals were analyzed using the Theta/Alpha Ratio and Huang Index derived from an existing nonlineardementia screening model.Results: The Theta/Alpha Ratio was higher in the cognitive impairment group, consistent with EEG slowing findings. The Huang Index achieved an accuracy of 0.84 and an AUC of 0.81, demonstrating the feasibility of cognitive impairment risk discrimination using wearable EEG.Conclusion: This study developed a wearable multi-physiological signal device and preliminarily validated its application as a dementia screening support tool in community settings. After obtaining medical device certification, the system may support future clinical research and health monitoring applications.
nity applications.Objective: This study aimed to develop a wearable multi-physiological signal device integrating medical device regulatory requirements and EEG analysis for community based cognitive impairment risk screening with improved affordability, accessibility, and accu
racy.Materials and Methods: A wearable device was developed to acquire EEG, electrocardiography (ECG), electrooculography (EOG), and three-axis acceleration signals. Participantswere recruited from community settings and dementia care sites, and resting-state EEG signals were analyzed using the Theta/Alpha Ratio and Huang Index derived from an existing nonlineardementia screening model.Results: The Theta/Alpha Ratio was higher in the cognitive impairment group, consistent with EEG slowing findings. The Huang Index achieved an accuracy of 0.84 and an AUC of 0.81, demonstrating the feasibility of cognitive impairment risk discrimination using wearable EEG.Conclusion: This study developed a wearable multi-physiological signal device and preliminarily validated its application as a dementia screening support tool in community settings. After obtaining medical device certification, the system may support future clinical research and health monitoring applications.