高級氧化程序 Far UVC₂₂₂ ₙₘ/chlorination 降解飲用水中微污染物及消毒副產物生成之研究
Degradation of Micropollutant in Drinking Water by Far UVC₂₂₂ ₙₘ/Chlorination Advanced Oxidation Process and Formation of Disinfection Byproducts
摘要
隨著人口成長與工業發展,越來越多合成化學物質經由排放進入環境,並最終匯集於地表水體,形成各類微量有機污染物,部分飲用水處理廠之水源因受到污染,可能對飲用水安全構成風險。為提升傳統飲用水處理程序對微量污染物的去除能力,高級氧化處理程序(Advanced Oxidation Processes, AOPs)已被應用於荷蘭歐港自來水公司及北荷蘭省飲用水公司,其中以UV/H₂O₂為目前的技術。然而,過氧化氫在254 nm波長下光能利用效率有限,且系統殘留過氧化氫需透過加氯去除,增加處理成本。因此,許多專家學者之研究建議改以UV/HOCl取代UV/H2O2。
在含氨氮的水體中,次氯酸會與氨反應形成氯胺物種,並在氯與氨反應[YC4.1]過程中生成一氯胺、二氯胺及三氯胺等多種氯胺。研究指出,在222 nm波長下,二氯胺及三氯胺的莫爾吸光係數明顯高於254 nm下的吸光能力,顯示222 nm較有利於氯胺物種吸收光子,並產生活性自由基,進而提升微量污染物的降解效率。故本研究以含有氨氮的Far UVC222 nm/chlorination作為研究系統,評估此程序是否能提高含氯物種的光能利用效率,並強化污染物的去除效果。
本研究以台北市某淨水廠快濾池出流水為背景水,並添加六種代表性微量污染物(Atenolol、Carbamazepine、Benzoic acid、Nitrobenzene、1,4-dioxane及DEET)。實驗比較水中含有氨氮的條件下,Far UVC222 nm/chlorination與傳統UVC254 nm/H₂O₂之污染物降解效能,以評估不同紫外光高級氧化處理程序的處理效能。此外,考量含氯高級氧化程序可能生成消毒副產物,本研究亦評估Far UVC222 nm/chlorination與UVC254 nm/H₂O₂於反應過程中消毒副產物的生成情形。
研究結果顯示,相較於UVC254 nm/H₂O₂,含有氨氮的Far UVC222 nm/chlorination於環形反應器中具有較佳的污染物降解效能,以1,4-dioxane的效率相比,Far UVC222 nm/chlorination的降解效能為UVC254 nm/H₂O₂的2.54倍。然而,消毒副產物於氨氮濃度為20 μM條件下的分析結果顯示,Far UVC222 nm/chlorination生成消毒副產物的量高於UVC254 nm/H₂O₂,但TIC-Tox毒性指標的結果顯示,Far UVC222 nm/chlorination較UVC254 nm/H₂O₂低約11.91 %。因此,飲用水處理廠處理受污染的水源時,Far UVC222 nm/chlorination未來有機會成為飲用水廠的替代技術。
在含氨氮的水體中,次氯酸會與氨反應形成氯胺物種,並在氯與氨反應[YC4.1]過程中生成一氯胺、二氯胺及三氯胺等多種氯胺。研究指出,在222 nm波長下,二氯胺及三氯胺的莫爾吸光係數明顯高於254 nm下的吸光能力,顯示222 nm較有利於氯胺物種吸收光子,並產生活性自由基,進而提升微量污染物的降解效率。故本研究以含有氨氮的Far UVC222 nm/chlorination作為研究系統,評估此程序是否能提高含氯物種的光能利用效率,並強化污染物的去除效果。
本研究以台北市某淨水廠快濾池出流水為背景水,並添加六種代表性微量污染物(Atenolol、Carbamazepine、Benzoic acid、Nitrobenzene、1,4-dioxane及DEET)。實驗比較水中含有氨氮的條件下,Far UVC222 nm/chlorination與傳統UVC254 nm/H₂O₂之污染物降解效能,以評估不同紫外光高級氧化處理程序的處理效能。此外,考量含氯高級氧化程序可能生成消毒副產物,本研究亦評估Far UVC222 nm/chlorination與UVC254 nm/H₂O₂於反應過程中消毒副產物的生成情形。
研究結果顯示,相較於UVC254 nm/H₂O₂,含有氨氮的Far UVC222 nm/chlorination於環形反應器中具有較佳的污染物降解效能,以1,4-dioxane的效率相比,Far UVC222 nm/chlorination的降解效能為UVC254 nm/H₂O₂的2.54倍。然而,消毒副產物於氨氮濃度為20 μM條件下的分析結果顯示,Far UVC222 nm/chlorination生成消毒副產物的量高於UVC254 nm/H₂O₂,但TIC-Tox毒性指標的結果顯示,Far UVC222 nm/chlorination較UVC254 nm/H₂O₂低約11.91 %。因此,飲用水處理廠處理受污染的水源時,Far UVC222 nm/chlorination未來有機會成為飲用水廠的替代技術。
With population growth and industrial development, increasing amounts of synthetic chemicals are released into the environment and eventually enter surface waters, resulting in the occurrence of various organic micropollutants. Contamination of source waters by these micropollutants may pose potential risks to drinking water safety. To enhance the removal of micropollutants by conventional drinking water treatment processes, advanced oxidation processes (AOPs) have been applied by drinking water utilities in the Netherlands, including those in the Port of Rotterdam and North Holland. Among these technologies, UV/H₂O₂ is currently a widely applied AOP. However, H₂O₂ exhibits relatively low light absorption at 254 nm, resulting in limited utilization of UV energy. In addition, residual H₂O₂ after treatment requires an additional removal step, such as chlorination, which may increase treatment costs. Therefore, UV/HOCl has been proposed as a potential alternative to UV/H₂O₂.
In ammonia-containing water, hypochlorous acid reacts with ammonia to form chloramine species, including monochloramine, dichloramine, and trichloramine. Previous studies have shown that the molar absorption coefficients of NHCl₂ and NCl₃ at 222 nm are substantially higher than those at 254 nm, indicating that Far UVC irradiation at 222 nm favors photon absorption by chloramine species and may enhance the generation of reactive radicals, thereby promoting micropollutant degradation. Accordingly, this study investigated Far UVC222 nm/chlorination in ammonia-containing water to evaluate whether this process could enhance photon utilization by chlorine-containing species and improve micropollutant degradation.
Rapid filter effluent collected from a drinking water treatment plant in Taipei City was used as the background water, and six representative micropollutants, including atenolol, carbamazepine, benzoic acid, nitrobenzene, 1,4-dioxane, and DEET, were spiked into the water. Under ammonia-containing conditions, the micropollutant degradation performance of Far UVC222 nm/chlorination was compared with that of conventional UVC254 nm/H₂O₂ to evaluate the treatment performance of these two UV-based AOPs. In addition, because chlorine-based AOPs may promote the formation of disinfection by-products (DBPs), DBP formation during Far UVC222 nm/chlorination and UVC254 nm/H₂O₂ treatment was also evaluated.
The results showed that Far UVC222 nm/chlorination under ammonia-containing conditions exhibited greater micropollutant degradation performance than UVC254 nm/H₂O₂ in an annular reactor. For 1,4-dioxane, the degradation performance of Far UVC222 nm/chlorination was 2.54-fold that of UVC254 nm/H₂O₂. DBP analysis conducted at an ammonia concentration of 20 μM showed that Far UVC222 nm/chlorination resulted in higher DBP formation than UVC254 nm/H₂O₂. Nevertheless, the TIC-Tox toxicity index of Far UVC222 nm/chlorination was approximately 11.91% lower than that of UVC254 nm/H₂O₂. Overall, these results demonstrate that Far UVC222 nm/chlorination can provide effective micropollutant degradation while maintaining a relatively low predicted toxicity associated with DBPs. Therefore, Far UVC222 nm/chlorination shows potential as an alternative AOP for drinking water treatment plants treating micropollutant-contaminated source waters.
In ammonia-containing water, hypochlorous acid reacts with ammonia to form chloramine species, including monochloramine, dichloramine, and trichloramine. Previous studies have shown that the molar absorption coefficients of NHCl₂ and NCl₃ at 222 nm are substantially higher than those at 254 nm, indicating that Far UVC irradiation at 222 nm favors photon absorption by chloramine species and may enhance the generation of reactive radicals, thereby promoting micropollutant degradation. Accordingly, this study investigated Far UVC222 nm/chlorination in ammonia-containing water to evaluate whether this process could enhance photon utilization by chlorine-containing species and improve micropollutant degradation.
Rapid filter effluent collected from a drinking water treatment plant in Taipei City was used as the background water, and six representative micropollutants, including atenolol, carbamazepine, benzoic acid, nitrobenzene, 1,4-dioxane, and DEET, were spiked into the water. Under ammonia-containing conditions, the micropollutant degradation performance of Far UVC222 nm/chlorination was compared with that of conventional UVC254 nm/H₂O₂ to evaluate the treatment performance of these two UV-based AOPs. In addition, because chlorine-based AOPs may promote the formation of disinfection by-products (DBPs), DBP formation during Far UVC222 nm/chlorination and UVC254 nm/H₂O₂ treatment was also evaluated.
The results showed that Far UVC222 nm/chlorination under ammonia-containing conditions exhibited greater micropollutant degradation performance than UVC254 nm/H₂O₂ in an annular reactor. For 1,4-dioxane, the degradation performance of Far UVC222 nm/chlorination was 2.54-fold that of UVC254 nm/H₂O₂. DBP analysis conducted at an ammonia concentration of 20 μM showed that Far UVC222 nm/chlorination resulted in higher DBP formation than UVC254 nm/H₂O₂. Nevertheless, the TIC-Tox toxicity index of Far UVC222 nm/chlorination was approximately 11.91% lower than that of UVC254 nm/H₂O₂. Overall, these results demonstrate that Far UVC222 nm/chlorination can provide effective micropollutant degradation while maintaining a relatively low predicted toxicity associated with DBPs. Therefore, Far UVC222 nm/chlorination shows potential as an alternative AOP for drinking water treatment plants treating micropollutant-contaminated source waters.