Smart Elevator with Reconfigurable Sensor Monitoring
具可重構感測器監測功能之智慧電梯系統
Files
The full text will be available from Aug 19, 2027.
Date
2026
Type
Department
Language
英文
Abstract
電梯系統極需可靠的運行監測機制,以確保安全性與效能,並在感測器配置可能隨時間變動的環境中,實現高效的故障偵測。傳統方法大多高度依賴專家知識與規則型系統(rule-based systems),因而限制了系統的擴充性與適應力。隨著物聯網(IoT)技術的興起,即時資料收集與智慧化故障分析已更具可行性與成效。
為解決上述瓶頸,本研究提出一套基於物聯網的電梯運行監測系統——ElevatorTalk-M。本系統引入一套創新的有限狀態機(FSM)框架,能針對任意感測器配置動態生成運行模型。延續早期 ElevatorTalk 平台的架構,ElevatorTalk-M 支援感測器的動態熱插拔與調整,並同時維持精準且一致的運行建模能力。此特性為現有智慧電梯解決方案所缺乏,對於既有舊式電梯的升級改造尤具實用價值。
實驗結果顯示,本系統能成功偵測所有門阻事件,平均偵測延遲僅 0.1 秒。此外,本研究進一步針對所提出的故障偵測演算法進行形式化正確性證明。透過整合輔助振動感測器,系統能顯著提升偵測可靠度,將偵測錯誤率從 0.18% 大幅降低至 0.0054%。上述結果表明,ElevatorTalk-M 提供了一套具備高擴充性、可解釋性與強韌性的解決方案,在提升電梯即時運行監測能力的同時,亦有效降低了對領域專家的依賴。
為解決上述瓶頸,本研究提出一套基於物聯網的電梯運行監測系統——ElevatorTalk-M。本系統引入一套創新的有限狀態機(FSM)框架,能針對任意感測器配置動態生成運行模型。延續早期 ElevatorTalk 平台的架構,ElevatorTalk-M 支援感測器的動態熱插拔與調整,並同時維持精準且一致的運行建模能力。此特性為現有智慧電梯解決方案所缺乏,對於既有舊式電梯的升級改造尤具實用價值。
實驗結果顯示,本系統能成功偵測所有門阻事件,平均偵測延遲僅 0.1 秒。此外,本研究進一步針對所提出的故障偵測演算法進行形式化正確性證明。透過整合輔助振動感測器,系統能顯著提升偵測可靠度,將偵測錯誤率從 0.18% 大幅降低至 0.0054%。上述結果表明,ElevatorTalk-M 提供了一套具備高擴充性、可解釋性與強韌性的解決方案,在提升電梯即時運行監測能力的同時,亦有效降低了對領域專家的依賴。
Elevator systems require robust operation monitoring to ensure safety, performance, and effective fault detection, particularly in environments where sensor configurations may evolve over time. Traditional approaches often rely heavily on expert knowledge and rule-based systems, limiting scalability and responsiveness. With the advent of IoT technologies, real-time data collection and intelligent fault analysis have become both feasible and effective. To address these limitations, we present ElevatorTalk-M, an IoT-based elevator operation monitoring system that introduces a novel finite state machine (FSM)-based framework capable of dynamically generating operational models for arbitrary sensor configurations. Building on the earlier ElevatorTalk platform, ElevatorTalk-M enables sensors to be added or removed transparently while maintaining accurate and consistent operational modeling, a capability that is not available in existing smart elevator solutions and is particularly beneficial for legacy elevators. Experimental results show that all door obstruction events are successfully detected with an average detection time of 0.1 seconds. We further provide a formal correctness proof of the proposed fault detection algorithm. By integrating an auxiliary vibration sensor, the system can significantly enhance detection reliability, reducing the detection error from 0.18% to 0.0054%. These results demonstrate that ElevatorTalk-M offers a scalable, interpretable, and resilient solution that reduces reliance on domain experts while improving real-time elevator operation monitoring.
Collections
Institute of Artificial Intelligence InnovationCite this item
Meng, H. J. (2026). Smart Elevator with Reconfigurable Sensor Monitoring. https://thesis.lib.nycu.edu.tw/handle/20.500.14371/91049
Citation generated in APA 7th edition style; please check it before use.
Share
Permanent link: https://thesis.lib.nycu.edu.tw/handle/20.500.14371/91049