X型加勁剪力消能耐震間柱之耐震行為與設計建議

A Study on Seismic Behaviors and Design Recommendations of Seismic Stud Columns with X-Type Stiffeners

檔案

日期

2026

類型

語言

中文

摘要

台灣身處地震帶,建物之側向抗震能力為耐震設計之核心課題。耐震間柱(seismic stud column, SSC)常配置於鋼框架內,平時承受風力維持勁度,於地震發生時透過降伏進行塑性消能,以保護主結構。然而傳統耐震間柱常因腹板過早挫曲導致強度驟降。為了改善此問題,本研究引入斜撐阻尼X型加勁板的設計,於間柱核心段配置加勁板。
本研究結合理論解析與有限元素模擬兩大主軸,理論推導方面,基於考量剪力變形之Timoshenko梁理論並引入整體扣除法,推導出能夠精確預測間柱之彈性側向勁度公式。數值模擬方面,利用ANSYS建立有限元素模型,針對腹板厚度比、加勁板後度、核心段占比,進行彈性與非彈性挫曲模擬分析
結果顯示,理論公式能夠準確預測模擬的彈性勁度值。X型加勁板能夠有效分割並抑制腹板挫曲波型。核心段配置建議在0.2~0.6。薄腹板之加勁版建議不超過20毫米。腹板厚度建議往薄腹板選取。
Taiwan is located in a high-seismicity zone, making the lateral earthquake resistance of buildings a central priority in structural design. Seismic Stud Columns (SSCs) are commonly placed within steel frames to provide lateral stiffness under daily wind loads and to dissipate energy through plastic yielding during severe earthquakes, thereby protecting the primary structure. However, conventional seismic stud columns are vulnerable to premature web buckling, leading to a sudden loss of strength. To address this issue, this study incorporates X-type stiffeners—inspired by brace-type dampers—into the core segment of the stud column.
This study combines theoretical analysis and numerical simulation. In the theoretical derivation, an elastic lateral stiffness formula capable of accurately predicting the stiffness of stud columns is established based on Timoshenko beam theory (which accounts for shear deformation) and the overall subtraction method. In the numerical simulation, finite element models are constructed using ANSYS to perform elastic and inelastic buckling analyses across key parameters, including the web thickness ratio, stiffener thickness, and core length ratio.
The results show that the proposed theoretical formula accurately predicts the elastic stiffness obtained from numerical simulations. The X-type stiffeners effectively subdivide the web and suppress out-of-plane buckling modes. Based on these findings, a core length ratio between 0.2 and 0.6 is recommended. For columns with thin webs, the stiffener thickness should not exceed 20 mm, and selecting a thinner web profile is recommended for design optimization.

所屬典藏

土木工程學系
顯示完整詮釋資料 統計資料

引用此條目

郭泳成 (2026). X型加勁剪力消能耐震間柱之耐震行為與設計建議. https://thesis.lib.nycu.edu.tw/handle/20.500.14371/91096

BibTeX RIS

引用文字依 APA 第 7 版格式自動產生,使用前請再核對。

分享