以金屬進樣管為游離源之常壓游離質譜法
A Metal Inlet-based Ambient Ionization Mass Spectrometry
摘要
因為常壓游離質譜法的簡便性和實用性,自21世紀初被開發出來之後,常壓游離質譜法已經迅速地被發展成一新興研究領域。不少常壓游離質譜法都是利用電暈放電的大氣壓下游離質譜法,或電噴灑游離質譜法的原理及概念所發展出來的。在常壓游離質譜法中,為使樣品的進樣更順利,一般均會將一客製化的金屬進樣管安裝在質譜儀的進樣端。在本論文中,我們將一根直徑約為50微米細銅線纏繞在金屬進樣管的前端,直接當作游離源。由於質譜儀的進樣端施加了如-6000伏特的高電壓,可誘使纏繞在金屬進樣管的細銅線前端產生類似電暈放電的效果,而能游離氣態分析物。基本上,只要將凝相態的樣品放置在金屬進樣管的下方,來自於樣品中具揮發性和半揮發性分析物就可以容易地被此游離裝置游離。因為此裝置相當簡單,我們也成功地使用金屬進樣管上纏繞有細銅線的游離源做為結合常壓游離質譜法與紫外-可見光吸收光譜法的聯用技術之聯結界面。當將手持式吸收光譜儀放置在質譜儀的金屬進樣管下方,來自於樣品的高揮發性或半揮發性分析物可同時被質譜與吸收光譜測到相對應的質譜圖和吸收光譜圖。此外,當將含有極性和非極性分析物樣品液滴(20 μL)放置在離金屬樣品進樣管僅1-2 mm的距離,極性和非極性分析物分子可利用此裝置同時被游離,並出現在同一張質譜圖上。總結而言,本研究成功開發了一種簡單的游離方法,可對不同極性的分析物進行游離化,因此基於所發展的游離方法的簡單性、低成本和具快速分析的特性,我們相信此新式游離源應具有進一步應用於分析實際樣品中各種不同極性分析物之潛力。
Ambient ionization mass spectrometry (AIMS) has undergone rapid and extensive development due to its simplicity and usefulness since its development at the beginning of the 21st century. The concepts of atmospheric pressure chemical ionization (APCI), specifically corona discharge, or electrospray ionization (ESI) have played a crucial role in the advancement of various AIMS techniques. In AIMS, a metal inlet is commonly incorporated into the orifice of the mass spectrometer to facilitate easy sample introduction. In this thesis, we demonstrated that a metal inlet coiled with a copper wire (~50 μm) can serve as the ion source directly. The orifice was subjected to a high voltage (e.g., -6000 V) to induce a corona discharge-like process at the front end of the copper wire coiled on the metal inlet, thereby facilitating the ionization of gaseous analytes surrounding the metal inlet. Essentially, this ionization approach enables the ionization of volatile and semi-volatile analytes derived from the sample in the condensed phase. By simply placing the sample underneath the metal inlet, analytes derived from the sample can be readily ionized using the developed ionization method. Thanks to its simplicity, we successfully demonstrated the combination of AIMS and ultraviolet-visible (UV-Vis) absorption spectroscopy as a hyphenated technique using our ionization method as the interface. By positioning a handheld absorption spectrometer under the metal inlet of the mass spectrometer, analytes with high volatility or semi-volatility can be simultaneously detected by MS and UV-Vis absorption spectroscopy. Furthermore, we also demonstrated the feasibility of utilizing the developed ionization setup for the simultaneous analysis of polar and nonpolar analytes from a sample droplet (~20 μL) placed near (1-2 mm) the inlet of the mass spectrometer. In summary, this study successfully developed a new ionization method capable of ionizing analytes with varying polarities. We believe that the developed AIMS hold the potential for further extension of its applications to real-world samples owing to its simplicity, low cost, and speed.