以金屬進樣管為游離源之常壓游離質譜法
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.catalog.0080 |
241114 | |
dc.catalog.00818 |
a | |
dc.catalog.00818 |
d | |
dc.catalog.00818 |
| | |
dc.catalog.00818 |
| | |
dc.catalog.0087 |
2023 | |
dc.catalog.020 |
平裝 | |
dc.catalog.041 |
chi | |
dc.catalog.041 |
eng | |
dc.catalog.300c |
30 | |
dc.contributor.advisor |
陳月枝 | |
dc.contributor.advisor |
Chen, Yu-Chie | |
dc.contributor.author |
杜奇峰 | |
dc.contributor.author |
Tu, Chi-Feng | |
dc.contributor.campus |
光復 | |
dc.contributor.college |
理學院 | |
dc.contributor.committee |
劉學儒 | |
dc.contributor.committee |
黃郁棻 | |
dc.contributor.committee |
Liu, Hsueh-Ju | |
dc.contributor.committee |
Huang, Yu-Fen | |
dc.contributor.department |
應用化學系 | |
dc.contributor.dpcode |
APCHG | |
dc.contributor.idpcode |
3654 | |
dc.contributor.studentid |
310654074 | |
dc.date.NCLavailable |
不公開 | |
dc.date.USTavailable |
不公開 | |
dc.date.etdavailablereason |
論文內容為即將發表之期刊內容,是為研究機密或為專利 | |
dc.date.issued |
2023 | |
dc.date.issuedROC |
112 | |
dc.date.paperavailable |
2024/09/14 | |
dc.date.schoolyear |
112 | |
dc.description.abstract |
因為常壓游離質譜法的簡便性和實用性,自21世紀初被開發出來之後,常壓游離質譜法已經迅速地被發展成一新興研究領域。不少常壓游離質譜法都是利用電暈放電的大氣壓下游離質譜法,或電噴灑游離質譜法的原理及概念所發展出來的。在常壓游離質譜法中,為使樣品的進樣更順利,一般均會將一客製化的金屬進樣管安裝在質譜儀的進樣端。在本論文中,我們將一根直徑約為50微米細銅線纏繞在金屬進樣管的前端,直接當作游離源。由於質譜儀的進樣端施加了如-6000伏特的高電壓,可誘使纏繞在金屬進樣管的細銅線前端產生類似電暈放電的效果,而能游離氣態分析物。基本上,只要將凝相態的樣品放置在金屬進樣管的下方,來自於樣品中具揮發性和半揮發性分析物就可以容易地被此游離裝置游離。因為此裝置相當簡單,我們也成功地使用金屬進樣管上纏繞有細銅線的游離源做為結合常壓游離質譜法與紫外-可見光吸收光譜法的聯用技術之聯結界面。當將手持式吸收光譜儀放置在質譜儀的金屬進樣管下方,來自於樣品的高揮發性或半揮發性分析物可同時被質譜與吸收光譜測到相對應的質譜圖和吸收光譜圖。此外,當將含有極性和非極性分析物樣品液滴(20 μL)放置在離金屬樣品進樣管僅1-2 mm的距離,極性和非極性分析物分子可利用此裝置同時被游離,並出現在同一張質譜圖上。總結而言,本研究成功開發了一種簡單的游離方法,可對不同極性的分析物進行游離化,因此基於所發展的游離方法的簡單性、低成本和具快速分析的特性,我們相信此新式游離源應具有進一步應用於分析實際樣品中各種不同極性分析物之潛力。 | |
dc.description.abstract |
Ambient ionization mass spectrometry (AIMS) has undergone rapid and extensive development due to its simplicity and usefulness since its development at the beginning of the 21st century. The concepts of atmospheric pressure chemical ionization (APCI), specifically corona discharge, or electrospray ionization (ESI) have played a crucial role in the advancement of various AIMS techniques. In AIMS, a metal inlet is commonly incorporated into the orifice of the mass spectrometer to facilitate easy sample introduction. In this thesis, we demonstrated that a metal inlet coiled with a copper wire (~50 μm) can serve as the ion source directly. The orifice was subjected to a high voltage (e.g., -6000 V) to induce a corona discharge-like process at the front end of the copper wire coiled on the metal inlet, thereby facilitating the ionization of gaseous analytes surrounding the metal inlet. Essentially, this ionization approach enables the ionization of volatile and semi-volatile analytes derived from the sample in the condensed phase. By simply placing the sample underneath the metal inlet, analytes derived from the sample can be readily ionized using the developed ionization method. Thanks to its simplicity, we successfully demonstrated the combination of AIMS and ultraviolet-visible (UV-Vis) absorption spectroscopy as a hyphenated technique using our ionization method as the interface. By positioning a handheld absorption spectrometer under the metal inlet of the mass spectrometer, analytes with high volatility or semi-volatility can be simultaneously detected by MS and UV-Vis absorption spectroscopy. Furthermore, we also demonstrated the feasibility of utilizing the developed ionization setup for the simultaneous analysis of polar and nonpolar analytes from a sample droplet (~20 μL) placed near (1-2 mm) the inlet of the mass spectrometer. In summary, this study successfully developed a new ionization method capable of ionizing analytes with varying polarities. We believe that the developed AIMS hold the potential for further extension of its applications to real-world samples owing to its simplicity, low cost, and speed. | |
dc.description.abstractopendate |
2023/09/07 | |
dc.description.degree |
碩士 | |
dc.description.tableofcontents |
謝 誌 ii 摘 要 iii Abstract iv Table of Contents v List of Figures vii List of Table x CHAPTER 1 1 Introduction 1 1-1. Background of Mass Spectrometry 1 1-1-1. ESI 2 1-1-2 APCI 2 1-2. Ambient Ionization MS 4 1-3. Contactless Ionization Techniques 5 1-3-1. Contactless Atmospheric Pressure Ionization 6 1-3-2. Ultrasonic Assisted Spray Ionization 8 1-3-3. Polarization-induced ESI 8 1-3-4. Carbon Fiber Ionization 9 1-3-5. Insulating Fiber-based Ionization 10 1-3-6. Atmospheric Surface-assisted Ionization 11 1-4. Dual ESI/APCI Ion Sources 13 1-5. Motivation and Research Goals 16 CHAPTER 2 18 Experimental Section 18 2-1. Experimental Details 18 2-1-1. Chemical and Materials 18 2-2 Instrumentation 18 2-3. Setup of the ionization method 19 2-4. Coupling an absorption spectrometer with MS 21 2-5. Analysis of simulated and real-world samples 22 CHAPTER 3 24 Results and Discussion 24 3-1. Using a metal inlet coiled with a copper wire as the ion source 24 3-2. Optimization of the experimental parameters 26 3-3. Analysis of volatiles and semivolatiles 29 3-4. Examination of limit of detection 37 3-5. Ionization mechanism of the developed approach 39 3-6. Coupling UV-Vis absorption spectroscopy with MS 43 3-7. Analysis of the mixture containing analytes with varying polarities 45 3-8. Analysis of sesame oil 49 CHAPTER 4 53 Conclusions and Perspectives 53 References 56 | |
dc.identifier.citation |
Brecht, D.; Uteschil, F.; Schmitz, O. J. Development of a fast-switching dual (ESI/APCI) ionization source for liquid chromatography/mass spectrometry. Rapid Commun. Mass Spectrom. 2020, 34, 8845. Carroll, D. I.; Dzidic, I.; Stillwell, R. N.; Haegele, K. D.; Horning, E. C. Atmospheric pressure ionization mass spectrometry. Corona discharge ion source for use in a liquid chromatograph-mass spectrometer-computer analytical system. Anal. Chem. 1975, 47, 2369 - 2373. Cody, R. B.; Laramée, J. A.; Durst, H. D, Versatile new ion source for the analysis of materials in open air under ambient conditions, Anal. Chem. 2005, 77, 2297 – 2302 Chen, T.-Y.; Wu, M.-L.; Chen, Y.-C. Ultrasonication‐assisted spray ionization‐based micro‐reactors for online monitoring of fast chemical reactions by mass spectrometry. J. Mass Spectrom. 2019, 54, 26 - 34. Cheng, S. C.; Huang, M. Z.; Shiea, J. Thin-layer chromatography/laser-induced acoustic desorption/electrospray ionization mass spectrometry. Anal. Chem., 2009, 81, 9274 – 9281 Cheng, C. Y.; Yuan, C. H.; Cheng, S. C.; Huang, M. Z.; Chang, H. C.; Cheng, T. L.; Shiea, J. Electrospray-assisted laser desorption/ionization mass spectrometry for continuously monitoring the states of ongoing chemical reactions in organic or aqueous solution under ambient conditions. Anal. chem. 2008, 80, 7699 - 7705. Chingin, K.; Chen, H.; Gamez, G.; Zhu, L.; Zenobi, R. Detection of diethyl phthalate in perfumes by extractive electrospray ionization mass spectrometry. Anal. Chem. 2009, 81, 123–129 Fenn, J. B.; Mann, M.; Meng, C. K.; Wong, S. F.; Whitehouse, C. M. Electrospray ionization for mass spectrometry of large biomolecules. Science. 1989, 246, 64 - 71. Gross, J. H. Mass spectrometry: A Textbook, 2017, 539 - 612, Springer. Grimm, R. L.; Beauchamp, J. L. Field-induced droplet ionization mass spectrometry. J. Phys. Chem. B. 2003, 107, 14161 - 14163. Haddad, R.; Milagre, H. M.; Catharino, R. R.; Eberlin, M. N, Easy ambient sonic-spray ionization mass spectrometry combined with thin-layer chromatography, Anal. Chem. 2008, 80, 2744 – 50 Harper, J. D.; Charipar, N. A.; Mulligan, C. C.; Zhang, X. R.; Cooks, R. G.; Ouyang, Z. Low-temperature plasma probe for ambient desorption ionization. Anal. Chem. 2008, 80, 9097 - 9104. Horning, E. C.; Carroll, D. I.; Dzidic, I.; Haegele, K. D.; Horning, M. G.; Stillwell, R. N., J. Chromatogr. A. 1974, 12, 725 Horning, E. C.; Carroll, D. I.; Dzidic, I.; Haegele, K. D.; Horning, M. G.; Stillwell, R. N. Liquid chromatograph-mass spectrometer-computer analytical systems: A continuous-flow system based on atmospheric pressure ionization mass spectrometry. J. Chromatogr. A. 1974, 99, 13 - 21. Hsieh, C.-H.; Chang, C.-H.; Urban, P. L.; Chen, Y.-C. Capillary action-supported contactless atmospheric pressure ionization for the combined sampling and mass spectrometric analysis of biomolecules. Anal. chem. 2011, 83, 2866 - 2869. Huang, D.-Y.; Tsai, J.-J.; Chen, Y.-C. Direct mass spectrometric analysis of semivolatiles derived from real samples at atmospheric pressure. ACS omega. 2022, 7, 10255 - 10261. Huang, D.-Y.; Wang, M.-J.; Wu, J.-J.; Chen, Y-C. Ionization of volatile organics and nonvolatile biomolecules directly from a titanium slab for mass spectrometric analysis. Molecules. 2021, 26, 6760. IARC. Some non-heterocyclic polycyclic aromatic hydrocarbons and some related exposures. IARC Monographs on the Evaluation of Carcinogenic Risks to Humans, 2010, 92, 1–853. Intra, P.; Yawootti, A.; Rattanadecho, P. Influence of the corona-wire diameter and length on corona discharge characteristics of a cylindrical tri-axial charger. J. Electrostat. 2015, 74, 37-46. Krieger, S.; Schmitz, O. J. Non-destructive plasticizer screening using a direct inlet probe atmospheric pressure chemical ionization source and ion trap mass spectrometry. Rapid Commun. Mass Spectrom. 2014, 28, 1862–1870. Kulyk, D.S.; Swiner, D.J.; Sahraeian, T.; Badu-Tawiah, A.K. Direct mass spectrometry analysis of complex mixtures by nanoelectrospray with simultaneous atmospheric pressure chemical ionization and electrophoretic separation capabilities. Anal Chem. 2019, 91, 11562 - 11568. Lin, S.-H.; Lo, T.-J.; Kuo, F.-Y.; Chen, Y.-C. Real time monitoring of accelerated chemical reactions by ultrasonication‐assisted spray ionization mass spectrometry. J. Mass Spectrom. 2014, 49, 50 - 56. Meher, A. K.; Chen, Y.-C. Tissue paper assisted spray ionization mass spectrometry. RSC advances. 2015, 5, 94315 - 94320. Meher, A. K.; Chen, Y.-C. Polarization induced electrospray ionization mass spectrometry for the analysis of liquid, viscous, and solid samples. J. Mass Spectrom. 2015, 50, 444-450. Meher, A. K.; Chen, Y.-C. Online monitoring of chemical reactions by polarization-induced electrospray ionization. Anal. Chim. Acta. 2016, 937, 106 - 112. Meher, A. K.; Chen, Y.-C. Analysis of volatile compounds by open-air ionization mass spectrometry. Anal. Chim. Acta. 2017, 966, 41 - 46. Nemes, P.; Vertes, A.; Laser ablation electrospray ionization for atmospheric pressure, in vivo, and imaging mass spectrometry. Anal. chem. 2007, 79, 8098 – 8106. Niessen, W. Liquid Chromatography Mass spectrometry. 2006, Taylor and Francis. Parmar, A.; Sharma, S. Derivative UV-vis absorption spectra as an invigorated spectrophotometric method for spectral resolution and quantitative analysis: Theoretical aspects and analytical applications: A review. TrAC, Trends Anal. Chem. 2016, 77, 44-53. Ratcliffe, L. V.; Rutten, F. J. M.; Barrett, D. A.; Whitemore, T.; Seymour, D.; Greenwood, C.; Aranda-Gonzalvo, Y.; Robinson, S.; McCoustra, M. Surface analysis under ambient conditions using plasma-assisted desorption/ionization mass spectrometry. Anal. Chem. 2007, 79, 6094 – 6101 Rozentale, I.; Lun, A. Y.; Zacs, D.; Bartkevics, V. The occurrence of polycyclic aromatic hydrocarbons in dried herbs and spices, Food Control, 2018, 83, 45-53. Sari, J. N.; Kandasamy, K.; Chen, Y.-C. Detection of Escherichia coli by combining an affinity-based method with contactless atmospheric pressure ionization mass spectrometry. Separations. 2022, 9,13. Selvaprakash, K.; Chen, Y.-C. Using an insulating fiber as the sampling probe and ionization substrate for ambient ionization–mass spectrometric analysis of volatile, semi-volatile, and polar analytes. Anal. Bioanal. Chem. 2022, 414, 4633 - 4643. Shiea, J.; Huang, M.-Z.; HSu, H.-J.; Lee, C.-Y.; Yuan, C.-H.; Beech, I.; Sunner, J. Electrospray-assisted laser desorption/ionization mass spectrometry for direct ambient analysis of solids. Rapid Commun. Mass Spectrom. 2005, 19, 3701 – 3704. Shimoda, M.; Shiratsuchi, H.; Nakada, Y.; Wu, Y.; Osajima, Y. J. Agric. Food Chem., 1996, 44, 3909-3912 Takáts, Z.; Wiseman, J. M.; Cooks, R.G.; Ambient mass spectrometry using desorption electrospray ionization (DESI): instrumentation, mechanisms and applications in forensics, chemistry, and biology. J. Mass Spectrom. 2005, 40, 1261-1275. Tsai, J.-J.; Lai, Y.-T.; Chen, Y.-C. Using solid-phase microextraction coupled with reactive carbon fiber ionization-mass spectrometry for the detection of aflatoxin B1 from complex samples. Separations. 2022, 9, 199. Urban, P. L.; Chen, Y.-C.; Wang, Y.-S. Time-resolved Mass Spectrometry: from Concept to Applications. 2016, Wiley. Wu, M.-L.; Chen, T.-Y.; Chen, Y.-C.; Chen, Y.-C. Carbon fiber ionization mass spectrometry for the analysis of analytes in vapor, liquid, and solid phases. Anal. Chem. 2017, 89, 13458 – 13465 Wu, M.-L.; Wu, Y.-C.; Chen, Y.-C. Detection of pesticide residues on intact tomatoes by carbon fiber ionization mass spectrometry. Anal. Bioanal Chem. 2019, 411, 1095–1105. Wu, Y.-C.; Chen, Y.-C. Reactive carbon fiber ionization mass spectrometry for characterization of unsaturated hydrocarbons from plant aroma. Anal. Bioanal. Chem. 2020, 412, 5489–5497. | |
dc.identifier.uri |
https://hdl.handle.net/20.500.14371/545 | |
dc.language.iso |
英文 | |
dc.relation.page |
61 | |
dc.subject.keyword |
質譜法 | |
dc.subject.keyword |
金屬進樣管 | |
dc.subject.keyword |
電暈放電 | |
dc.subject.keyword |
常壓游離法 | |
dc.subject.keyword |
大氣壓下化學游離法 | |
dc.subject.keyword |
聯用技術 | |
dc.subject.keyword |
電噴灑與大氣壓下游離雙重游離法 | |
dc.subject.keyword |
Mass spectrometry | |
dc.subject.keyword |
metal inlet | |
dc.subject.keyword |
atmospheric pressure chemical ionization (APCI) | |
dc.subject.keyword |
corona discharge | |
dc.subject.keyword |
ambient ionization | |
dc.subject.keyword |
electrospray ionization (ESI) | |
dc.subject.keyword |
hyphenated techniques | |
dc.subject.keyword |
dual ESI/APCI ion sources | |
dc.title |
以金屬進樣管為游離源之常壓游離質譜法 | zh-TW |
dc.title |
A Metal Inlet-based Ambient Ionization Mass Spectrometry | en |
dc.type |
Thesis | zh-TW |
檔案
全文未公開。
所屬典藏: 應用化學系